888.221.8660 info@revivescientific.com
Cart 0

MVE Cryosystem 6000 with MVE TEC-3000 Controller

MVE Cryosystem 6000 with MVE TEC-3000 Controller

$2,995.00

This MVE Cryosystem 6000 w/ MVE TEC-300 has been Refurbished, Fully Tested, Inspected and Verified to be in Great Working Condition.

60 Day Warranty!

Includes: MVE Cryosystem 6000, MVE TEC-300, 4x Racks, Roller Wheel Base, LN2 Supply Hose, Thermometer, Lid and Power Cord and 

The MVE CryoSystem Series combines the benefits of low nitrogen consumption with mid-range vial capacity to meet the diverse needs of today’s professionals worldwide. The lightweight and low-space demands of these containers make them one of the most economical units in their class.

Key Features:

  • Designed for medium vial storage capacity
  • Low liquid nitrogen consumption
  • Optional rollerbase system for easy moveability
  • Durable Tamper - proof lid design
  • High strength neck tube reduces liquid nitrogen loss
  • Advanced chemical vacuum retention system
  • Insulation to provide maximum thermal performance
  • Convenient, strong, lightweight aluminum construction
  • Spider design for easy retrieval and insertion of product canisters
  • Cork & cover
  • 6 hanging canisters for 2" square vial boxes
  • TWO Year Parts Warranty • THREE Year Vacuum Warranty
  • Conforms to MDD 93/42/EEC, the Medical Device Directive for the EU

About: TEC 3000

The TEC 3000 employs a variety of advanced features that enable the controller to monitor and control the environment inside a freezer with a high level of precision.

Liquid Nitrogen Level Measurement

  • The TEC 3000 uses a differential pressure system to determine
    the LN2 level to an accuracy of± 0.5 in. (15 mm) and a resolution
    ofO.l in. (5.0 mm). Unlike alternative level sensing systems,
    differential pressure allows the exact level to be measured and
    displayed. Using the simple single point calibration in a range
    of 3.0 in. to 48.0 in. (75 mm to 1220 mm), the patented, selfmaintaining,
    closed-loop system displays in inches, millimeters,
    or a percentage full.

Automatic Liquid Nitrogen Level Control

  • The fully automated LN2 level control system is based on userdefined
    parameters that can be electronically adjusted over the
    entire level range. The parameters include Low Level Alarm, Low
    Level Fill Point, High Level Fill Point and High Level Alarm. The
    redundant Dual Solenoid Valves for overfill protection run on 24
    VDC, 1.0 amp (max).

Liquid Usage

  • This exclusive feature provides an estimation of liquid usage to
    track LN2 consumption and can provide an early failure warning
    to allow sufficient time to implement corrective action and save
    irreplaceable samples.

User-Defined Alarms

  • A total of 17 audio/visual alarms are used to alert the user to any
    potential or developing problems. The alarms include: High
    Temperatures, Low Temperatures, High Level, Low Level, Liquid
    Usage, Maximum Fill Time, Gas Bypass, Temperature Calibrations,
    Low Battery, Power Failure, Lid Open and Communication
    Loss.

Remote Alarm Monitoring

  • The TEC 3000 Alarm monitoring includes a Global Remote
    Alarm Relay, as well as four discrete contacts for High Level,
    Low Level, Temp A High and Low Battery.

Temperature Measurement

  • Two independent temperature measurement channels are employed
    to accurately measure the temperature across the entire
    storage space. The two platinum RTD sensors have an accuracy
    of± l .0°C and a resolution of 0.1 °C. The temperature can be displayed
    in °C, °F or K. The single or two point calibration also has
    altitude compensation for the highest accuracy.

Hot Gas Bypass

  • This unique feature is able to vent warm nitrogen gas from the
    supply line before initiating a fill. This prevents warm gas from
    entering the freezer space, which helps maintain a stable temperature
    gradient and increases the efficiency by reducing excess
    LN2 evaporation.

Event Log / Data Storage

  • The TEC 3000 is able to store vital, unalterable, time-stamped
    data in nonvolatile memory. This is a great tool for assessing
    freezer performance and troubleshooting any problems. The
    memory can store 30,000 events, an estimated 10 years of storage
    capacity. The data includes time-stamped temperatures, LN2
    level, liquid usage, and any alarms or events.

Password Security

  • The multilevel security system comprised of up to ten userspecific
    programmable passwords and four security levels can
    be customized to grant or restrict personnel access to certain
    menus and settings.

Communication Capabilities

  • Two independent ports can be used to communicate with other
    TEC 3000 controllers, a remote PC, serial printer, or other RS-
    485 networks and devices. Options include ASCII, MOD BUS,
    Printer and One Fill All Fill (OFAF).

Product ID # 2654


Share this Product


More from this category